Rolling Stock Cables
EN 50264 EN 50306 EN 50382 Databus Cables NF F 63-826 NF F 63-808 NF F 63-827 RSE/STD/024 PART 6

  FRL-WTB-02YCH-2G0.75, FRL-WTB-02YCH-1P0.75S, FRL-WTB-02YCH-2P0.75S

    

                                                               A. Conductor B. Insulation C. Screen D. Sheath 

Application
The cables are designed for permanent installation inside of rolling stock to connect fixed parts. A typical application is a communication system in a locomotive. The system uses a wire backed bus system to the TCN standard for control and instrumentation and for diagnostics. This bus system consists of the rail bus WTB (Wired Train Bus) and the road bus MVB (Multifunction Vehicle Bus) which are connected via redundant gateways.

Construction
Conductors
Stranded tin plated copper conductor according to IEC 60228 class 5

Insulation
Foam PE or Foam Skin

Core Wrapping
Plastic tape(s)

EMC Screen
Tin plated copper braid

Outer Sheath
Cross-linked oil resistant LSZH compound

Electrical & Mechanical Properties
Nominal Voltage 300V
Maximum Temperature 100°C
Minimum Temperature -40°C
Bending Radius 10 x Overall Diameter

Chemical & Environmental Properties

EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to mineral oil & fuel oil, acid & alkali
EN 50305 Resistance to ozone

Fire Performance for rolling stock application

EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804
Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;
NF C 20-902; NF F 16 101; VDE 0472 Teil 816
Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 Low Corrosivity (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Low Toxicity
NFF 16101; NFF 63808; BS6853 Smoke index

FRL-WTB-02YCH-2G0.75

Nominal Cross Sectional Area

Number & Nominal Diameter of Strands

Nominal Sheath Thickness

Nominal Overall Diameter

Nominal Weight

Maximum Conductor Resistance

Impedance

Maximum Transfer Impedance

Maximum Attenuation

20℃

@1-10MHz

f<=30MHz

@1MHz

@1.5MHz

@2MHz

@3MHz

mm2

No/mm

mm

mm

kg/km

Ω/km

Ω

mΩ/m

dB/km

dB/km

dB/km

dB/km

0.75

19/0.22

1.4

8.3

97

26.7

120+/-12

30

10

13

14

18

FRL-WTB-02YCH-1P0.75S

Nominal Cross Sectional Area

Number & Nominal Diameter of Strands

Nominal Sheath Thickness

Nominal Overall Diameter

Nominal Weight

Maximum Conductor Resistance

Impedance

Maximum Transfer Impedance

Maximum Attenuation

20℃

@1-10MHz

f<=30MHz

@1MHz

@1.5MHz

@2MHz

@3MHz

mm2

No/mm

mm

mm

kg/km

Ω/km

Ω

mΩ/m

dB/km

dB/km

dB/km

dB/km

0.75

19/0.22

1.4

9.0

110

26.7

120+/-12

30

10

13

14

18

FRL-WTB-02YCH-2P0.75S

Nominal Cross Sectional Area

Number & Nominal Diameter of Strands

Nominal Sheath Thickness

Nominal Overall Diameter

Nominal Weight

Maximum Conductor Resistance

Impedance

Maximum Transfer Impedance

Maximum Attenuation

20℃

@1-10MHz

f<=30MHz

@1MHz

@1.5MHz

@2MHz

@3MHz

mm2

No/mm

mm

mm

kg/km

Ω/km

Ω

mΩ/m

dB/km

dB/km

dB/km

dB/km

0.75

19/0.22

1.4

11.4

150

26.7

120+/-12

30

10

13

14

18